• DocumentCode
    946261
  • Title

    Waveform Standards for Electrooptics: A Pulse Duration Comparison (Short Paper)

  • Author

    Lawton, Robert A. ; Meyer, Kevin

  • Volume
    35
  • Issue
    4
  • fYear
    1987
  • fDate
    4/1/1987 12:00:00 AM
  • Firstpage
    450
  • Lastpage
    453
  • Abstract
    A transfer standard has been developed for use in comparing the measurement capability of the Automatic Pulse Measurement System (APMS) at the National Bureau of Standards to that of the recently developed electrooptic samplers. This transfer standard is a comb generator driven by a 90-MHz sine wave. Using this standard, measurements were made of the pulse waveform of a comb generator output with both the APMS and an electrooptic sampler. A comparison was then made of the pulse duration (full width at half maximum) obtained in the two waveform measurements. The result was a duration of 102 ps as measured by the APMS and 112 ps as measured by the electrooptic sampler. The signal-to-noise ratio at the comb generator input was improved over that of previous measurements, and a correction for pulse broadening was made to achieve this result. The pulse broadening was caused by the impedance mismatch between the sampler and the transmission system (50 Omega).
  • Keywords
    Anisotropic magnetoresistance; Antennas and propagation; Boron; Dielectric constant; Dielectric substrates; Finline; Magnetic analysis; Measurement standards; Pulse measurements; Standards development;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1987.1133670
  • Filename
    1133670