• DocumentCode
    949903
  • Title

    Checking of square-law detectors used in Hartshorn and Ward dielectric measurements

  • Author

    Clarke, R.N.

  • Author_Institution
    National Physical Laboratory, Division of Electrical Science, Teddington, UK
  • Volume
    15
  • Issue
    6
  • fYear
    1979
  • Firstpage
    183
  • Lastpage
    184
  • Abstract
    It is shown that the ratio of resonance widths test, which is intended to check the square law of detectors used in Hartshorn and Ward measurements, does not give positive proof of compliance to a square-law characteristic. It is further shown that this test is insensitive to a likely form of departure from square law, which will give rise to errors in both conductance and loss-tangent measurements. An example is provided and general conclusions are drawn relating to the experimental verification of the compliance of detectors to a theoretical law.
  • Keywords
    detector circuits; dielectric measurement; Hartshorn and Ward dielectric measurements; resonance widths; square law detectors;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19790128
  • Filename
    4243054