Title :
Magnetic bubble mass memory
Author :
Michaelis, Paul C. ; Richards, W.J.
Author_Institution :
Bell Laboratories, Murray Hill, N.J.
fDate :
1/1/1975 12:00:00 AM
Abstract :
An experimental magnetic bubble mass memory module complete with all control function and detection electronics has been built and operated. The module contains twenty-eight 16 448-bit mass memory chips and operates at a nominal rotating field frequency of 100 kHz. The module has an average access time of 2.7 ms, a read/write cycle time of 5.14 ms, and a data rate of 700 kbit/sec. A read error rate of <1.6 × 1012and error-free propagation in excess of 8.4 × 1015bubble cycles have been demonstrated.
Keywords :
Magnetic bubble memories; Mass memories; Assembly; Bridges; Ceramics; Chip scale packaging; Detectors; Electronic equipment testing; Frequency; Noise cancellation; Substrates; Weight control;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1975.1058559