DocumentCode
953734
Title
Effect of Surface Contamination on the Thermocompression Bondability of Gold
Author
Jellison, Jawles L.
Author_Institution
Sandia Lab.
Volume
11
Issue
3
fYear
1975
fDate
9/1/1975 12:00:00 AM
Firstpage
206
Lastpage
211
Abstract
The recent development of a microshear test has made possible the quantitative study of the effect of surface contamination on thermocompression ball bonding of gold to gold metallization. Contarninant films were characterized by Auger electron spectroscopy and low energy ion spectroscopy. The thermocompression gold bonding process was found to be highly temperature dependent when organic films, which are barriers to metallic bonding, are present. Much of this temperature dependence could.be eliminated by rernoving the contaminant films by uV radiation prior to thermocompression bonding. Post-heat treatment resulted in the growth of metallic bond inter´faces, presumably by sintering mechanisms.
Keywords
Contamination; Gold; Surfaces; Thermocompression bonding; Bonding; Gold; Lamps; Metallization; Pollution measurement; Scanning electron microscopy; Surface contamination; Temperature; Testing; Wire;