Abstract
The authors have used the three-dimensional method to calculate the power deposition in the human pelvic region due to a radio-frequency current at 13.56 MHz applied through round or oval capacitive-plate applicators. They compare the energy deposited in several tumor sites when energy is applied using a variety of applicator sizes and locations and boluses of various conductivities. Detailed maps of the power deposition in the these cases for selected regions of the body are shown as well as useful applicator configurations for heating tumors at several locations in the body.
Keywords
biothermics; electrodes; patient treatment; radiofrequency heating; 13.56 MHz; 3D power deposition patterns; EM tumor heating; RF current; applicator sizes; boluses; capacitive plate electrodes; conductivities; energy deposited; human pelvic region; hyperthermia; impedance method; oval capacitive-plate applicators; power deposition; round capacitive-plate applicators; tumor sites; Applicators; Biological system modeling; Electrodes; Electromagnetic coupling; Heating; Humans; Hyperthermia; Impedance measurement; Neoplasms; Radio frequency; Computer Simulation; Electric Conductivity; Electrodes; Humans; Hyperthermia, Induced; Intestinal Neoplasms; Mathematical Computing; Models, Theoretical;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.43611
Filename
43611
Link To Document