DocumentCode
955127
Title
Assessment of Silicone Encapsulants for Hybrid Integrated Circuits (HIC)
Author
Christou, Aristos
Author_Institution
Naval Research Laboratory,Washington
Volume
13
Issue
3
fYear
1977
fDate
9/1/1977 12:00:00 AM
Firstpage
298
Lastpage
304
Abstract
A silicone encapsulant has been investigated as to its effectiveness in preventing migrated gold resistive shorts (MGRS). Using a temperature cycle of -10°C to +100°C, MGRS formation was observed at moisture levels of 0.9 to 1.2 percent V/V for Cl-, 1-, K+, and Na+ion contaminated environments. The results indicate that water molecules and halogen, Na+and K+ions will be readily transmitted through the silicone material. Dendritic growth has been found to occur when threshold water and ion levels were exceeded. A technique for measuring the kinetics Of moisture penetration through encapsulants is described. The method consists of utilizing moisture mi-. crosensors bonded within the candidate hybrid package; followed by microspot AES, EDXA analysis of ionic contamination. The test results from the hybrid moisture microsensors are compared with kinetics data´ obtained by measuring surface currents on .thermal SiO2 . Measured moisture and ionic contamination levels and the formation of MGRS in the presence of Na, I, K, Cl, S ions are summarized.
Keywords
Hybrid integrated circuit packaging; Bonding; Contamination; Gold; Hybrid integrated circuits; Kinetic theory; Moisture measurement; Packaging; Pollution measurement; Temperature; Water pollution;
fLanguage
English
Journal_Title
Parts, Hybrids, and Packaging, IEEE Transactions on
Publisher
ieee
ISSN
0361-1000
Type
jour
DOI
10.1109/TPHP.1977.1135200
Filename
1135200
Link To Document