Abstract :
A point-to-point, half-duplex link communication protocol for general telemetry applications that demand high reliability regarding information loss or distortion was developed. Despite its mentioned reliability, the protocol is based on a restricted set of rules, ideal for low-cost systems requiring little hardware. A controlled flow presenting no data loss or sequential data repetition was obtained with the inclusion of only 1 bit in the header of each packet for flow control. The most common applications of this protocol would be monitoring and control of medical devices, telemetry, and remote control in applications with low tolerance to failure.
Keywords :
packet radio networks; protocols; radiotelemetry; telecommunication network reliability; controlled flow; data loss; fault tolerance; flow control; half-duplex link communication protocol; medical devices; medical monitoring; point-to-point communication protocol; reliability; remote control; remote monitoring devices; sequential data repetition; telemetry; Biomedical monitoring; Communication system control; Condition monitoring; Control systems; Hardware; Medical control systems; Protocols; Remote monitoring; Telemetry; Testing;