DocumentCode
957994
Title
Out-of-core detector for power monitoring at commercial BWR plant
Author
Joshi, Arun N. ; Scheetz, Jeffrey C.
Author_Institution
Washington Public Power Supply Syst., Richland, WA, USA
Volume
35
Issue
1
fYear
1988
Firstpage
929
Lastpage
932
Abstract
To meet NRC (US Nuclear Regulatory Commission) regulatory requirements for post-accident power monitoring at a commercial BWR (boiling-water reactor) plant, an out-of-core (ex-core) neutron-flux detector to measure reactor power was evaluated and installed. Several multigroup calculations and measurements, which predicted sufficient flux leakage outside the vessel, are described in detail. Since BWR plants currently use only in-core detectors for flux monitoring, the ex-core detector installation required backfit inside the reactor shield wall. The modification of removable shield blocks was readily accomplished during a scheduled outage. It is concluded that some BWR plants can economically utilize excore flux monitors to meet regulatory requirements.<>
Keywords
fission reactor core control and monitoring; fission reactor instrumentation; neutron flux; radiation monitoring; BWR plant; ex-core detector; multigroup calculations; neutron flux leakage; neutron-flux detector; out-of-core detector; power monitoring; reactor power; Accidents; Detectors; Inductors; Instruments; Licenses; Monitoring; Neutrons; Power generation; Power supplies; Roentgenium;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher