• DocumentCode
    959270
  • Title

    Polymeric Sensors to Monitor Cockroach Locomotion

  • Author

    Lee, Hyungoo ; Cooper, Rodrigo ; Mika, Bartosz ; Clayton, David ; Garg, Rajesh ; González, Jorge M. ; Vinson, S. Bradleigh ; Khatri, Sunil ; Liang, Hong

  • Author_Institution
    Texas A&M Univ., Coll. Station
  • Volume
    7
  • Issue
    12
  • fYear
    2007
  • Firstpage
    1698
  • Lastpage
    1702
  • Abstract
    We have developed a method using a polyvinylidene fluoride (PVDF) polymeric sensor to monitor the leg movements of cockroaches. The PVDF sensor was coated with gold as electrodes. It was attached to the leg of a roach. The voltage signals generated through bending directly correlate to the movement of the legs. It was found that the output voltage was a function of the degree of sensor bending caused by the movement of leg sclerites. An ex situ motorized linear stage generated similar results.
  • Keywords
    biomechanics; biosensors; microsensors; biological sensors; cockroach leg movements monitoring; cockroach locomotion monitoring; electrodes; polyvinylidene fluoride polymeric sensor; voltage signals; Acoustic sensors; Biosensors; Gold; Intelligent sensors; Leg; Mechanical sensors; Monitoring; Piezoelectric materials; Polymers; Voltage; Biological sensors; cockroaches; polyvinylidene fluoride (PVDF) sensors;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2007.909624
  • Filename
    4373301