DocumentCode
959839
Title
Hydrostatic loading of magnetic liquid seals
Author
Perry, M.P. ; Jones, T.B.
Author_Institution
Colorado State University, Ft. Collins, Colorado
Volume
12
Issue
6
fYear
1976
fDate
11/1/1976 12:00:00 AM
Firstpage
798
Lastpage
800
Abstract
Ferromagnetic liquid, also called ferrofluid, is used extensively at the present time as a leakproof fluid seal between regions of different pressure. Ferrofluid "plugs" have been proposed to facilitate blood flow stasis in arteries during surgery as an alternative to present methods which cause arterial wall damage. The hydrostatic loading of ferrofluid is investigated theoretically and experimentally for liquid and air pressure loading. It is found that the Bernoulli equation, modified to account for magnetic field-ferrofluid coupling, adequately predicts the sealing capacity of the hydrostatic plug when the ferrofluid surfaces are in stable equilibrium. General criteria are outlined for the determination of the stability of various liquid-liquid and gas-liquid configurations. Loading measurements are independently correlated by vibrating magnetometer measurements.
Keywords
Arteries; Magnetic liquids; Seals; Arteries; Blood flow; Couplings; Equations; Magnetic field measurement; Magnetic liquids; Plugs; Seals; Surgery; Vibration measurement;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1976.1059196
Filename
1059196
Link To Document