Title :
On the Measurement of Total Radiated Power in Uncalibrated Reverberation Chambers
Author :
Krauthäuser, Hans Georg
Author_Institution :
Otto-von-Guericke-Univ., Magdeburg
fDate :
5/1/2007 12:00:00 AM
Abstract :
A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.
Keywords :
electric field measurement; electromagnetic fields; magnetic field measurement; reverberation chambers; IEC 61000-4-21; emission measurement; equipment under test; mode-stirred chamber; total radiated power; uncalibrated reverberation chamber; variable measurement; Calibration; Electromagnetic compatibility; Electromagnetic measurements; Frequency; IEC standards; Polarization; Power measurement; Receiving antennas; Reverberation chamber; Testing; Emission measurement; IEC 61000-4-21; mode-stirred chamber; reverberation chamber (RC); total radiated power;
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
DOI :
10.1109/TEMC.2007.897122