• DocumentCode
    961216
  • Title

    Thermal performance of the rotor of the MIT-EPRI 3 MVA superconducting alternator

  • Author

    Bejan, Adrian ; Thullen, Philip

  • Author_Institution
    University of California, Berkeley, CA
  • Volume
    13
  • Issue
    1
  • fYear
    1977
  • fDate
    1/1/1977 12:00:00 AM
  • Firstpage
    763
  • Lastpage
    766
  • Abstract
    The MIT-EPRI 3 MVA superconducting alternator has undergone a number of successful electrical and mechanical tests. During these tests a great deal of information on the thermal performance of the rotor has been collected. This information has not been presented in the literature or discussed generally. Thermal performance data of interest to generator designers such as: helium flow circuit behavior and conceptual design, electrical lead performance following reconstruction and shield thermal performance is discussed.
  • Keywords
    Rotating-machine thermal factors; Superconducting rotating machines; Synchronous generators; Alternators; Atmosphere; Circuit testing; Cooling; Cryogenics; Fluid flow control; Helium; Rotors; Temperature; Torque;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1977.1059338
  • Filename
    1059338