• DocumentCode
    966289
  • Title

    Effect of Measurement Conditions on Low-Level Contact Resistance

  • Author

    Muniesa, Jacques ; Mousson, Jean Yves

  • Volume
    7
  • Issue
    1
  • fYear
    1984
  • fDate
    3/1/1984 12:00:00 AM
  • Firstpage
    81
  • Lastpage
    83
  • Abstract
    The degradation of low-level contacts can be characterized the evaluation of their contact resistance with time. There is no doubt, vever, that the measurement conditions have a definite influence on the faults. This has been shown by tests made in a polluted atmosphere containing 0.5 ppm hydrogen sulfide and 1 ppm sulphur dioxide under controlled temperature and relative humidity Conditions. Contact resistance measurements were made on significant samples at a low-level voltage mV) and with direct currents ranging from 0.1 to 100 mA. This enabled contact resistance distribution to be determined and its evolution followed by day for silver contacts. It was found that a test current of 100 mA, not suitable for characterization of low-level contacts over a period of ee weeks.
  • Keywords
    Contacts; Resistance measurements; Atmosphere; Atmospheric measurements; Contact resistance; Degradation; Electrical resistance measurement; Humidity control; Hydrogen; Pollution measurement; Temperature control; Testing;
  • fLanguage
    English
  • Journal_Title
    Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0148-6411
  • Type

    jour

  • DOI
    10.1109/TCHMT.1984.1136335
  • Filename
    1136335