DocumentCode
966641
Title
Identification and open-loop tracking control of a piezoelectric tube scanner for high-speed scanning-probe microscopy
Author
Schitter, Georg ; Stemmer, Andreas
Author_Institution
Nanotechnology Group, Swiss Fed. Inst. of Technol. Zurich, Switzerland
Volume
12
Issue
3
fYear
2004
fDate
5/1/2004 12:00:00 AM
Firstpage
449
Lastpage
454
Abstract
Fast and precise positioning is a basic requirement for nanotechnology applications. Many scanning-probe microscopes (SPM) use a piezoelectric tube scanner for actuation with nanometer resolution in all three spatial directions. Due to the dynamics of the actuator, the imaging speed of the SPM is limited. By applying model-based open-loop control, the dynamic behavior of the scanner can be compensated, reducing the displacement error, topographical artifacts, modulation of the interaction force, and modulation of the relative tip-sample velocity. The open-loop controlled system enables imaging of up to 125-μm-sized samples at a line scan rate of 122 Hz, which is about 15 times faster than the commercial system.
Keywords
control system synthesis; dynamics; identification; nanopositioning; nanotechnology; optical scanners; piezoelectric actuators; position control; scanning probe microscopy; tracking; 122 Hz; actuator; dynamic behavior; high-speed scanning probe microscopy; nanotechnology application; open-loop tracking control; piezoelectric tube scanner; system identification; Actuators; Displacement control; Error correction; Force control; High-resolution imaging; Nanotechnology; Open loop systems; Scanning probe microscopy; Spatial resolution; Velocity control;
fLanguage
English
Journal_Title
Control Systems Technology, IEEE Transactions on
Publisher
ieee
ISSN
1063-6536
Type
jour
DOI
10.1109/TCST.2004.824290