DocumentCode :
968130
Title :
Panel capacitance estimation method for three-electrode AC-PDP
Author :
Lee, J.Y. ; Kim, Y.-S.
Author_Institution :
Electron. & Comput. Eng., Dankook Univ., Chungnam, South Korea
Volume :
42
Issue :
12
fYear :
2006
fDate :
6/8/2006 12:00:00 AM
Firstpage :
685
Lastpage :
687
Abstract :
A new approach for estimating AC-PDP parasitic capacitances is proposed. The method uses easily obtainable data such as resonant period of energy recovery and address power consumptions on specific test images for extracting the capacitances formed among three electrodes of scan (Y), sustain (X), and data electrodes. The proposed capacitance estimation method may assist in cell structure and system design.
Keywords :
capacitance measurement; electrodes; plasma displays; cell structure; data electrodes; energy recovery; panel capacitance estimation; parasitic capacitance; plasma display panels; power consumption; three-electrode AC-PDP;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20060229