• DocumentCode
    968401
  • Title

    Corrosion Failure Modes in a TAB200 Test Vehicle

  • Author

    Padmanabhan, Ramaswamy

  • Author_Institution
    Motorola Inc., Phoenix, AZ
  • Volume
    8
  • Issue
    4
  • fYear
    1985
  • fDate
    12/1/1985 12:00:00 AM
  • Firstpage
    435
  • Lastpage
    439
  • Abstract
    Temperature-humidity bias (THB) tests were carried out for tape automated bonded (TAB) samples, consisting of Au/Cu/Cr metal bump structures and AI/Si interconnecting metallization tracks, passivated with P-doped glass. Three predominant failure modes were identified: 1) type A failure: corrosion of positive and negative metallization tracks; 2) type B failure: corrosion at the bond pad-bump interfaces; and 3) type C failure: debonding of the Cu/Sn inner leads from the bumps. While type C failure was mainly due to improper bonding parameters and thus not directly related to the corrosion process, the other two types were caused by specific ionic impurities. Adhesion between the various metalpassivation interfaces and the quality of the passivation both had a major influence on the corrosion characteristics.
  • Keywords
    Corrosion; Integrated circuit bonding; Integrated circuit reliability; Integrated circuit thermal factors; Moisture control; Artificial intelligence; Automatic testing; Bonding; Chromium; Corrosion; Glass; Gold; Metallization; Tin; Vehicles;
  • fLanguage
    English
  • Journal_Title
    Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0148-6411
  • Type

    jour

  • DOI
    10.1109/TCHMT.1985.1136542
  • Filename
    1136542