• DocumentCode
    969708
  • Title

    Negative frequency aspects of doubly fed machine analysis

  • Author

    Ortmeyer, Thomas H.

  • Author_Institution
    Clarkson College, Potsdam, NY
  • Volume
    71
  • Issue
    8
  • fYear
    1983
  • Firstpage
    1017
  • Lastpage
    1017
  • Abstract
    Negative frequencies occur in the analysis of doubly fed machines. The properties of negative-frequency quantities are investigated and volt-amp relationships described, for both single-phase and three-phase circuits. Transformations of negative-frequency quantities to equivalent positive-frequency quantities are considered. A general equivalent circuit of the doubly fed machine is described which is directly applicable over the entire operating range.
  • Keywords
    Equivalent circuits; Frequency; Impedance; Power system dynamics; Power systems; Reactive power; Rotors; Stators; Steady-state; Voltage;