DocumentCode :
969867
Title :
A magnet system for the time projection chamber at PEP
Author :
Green, M.A. ; Eberhard, P.H. ; Taylor, J.D. ; Burns, W.A. ; Garfinkel, B. ; Gibson, G.H. ; Miller, P.B. ; Ross, R.R. ; Smits, R.G. ; Van Slyke, H.W.
Author_Institution :
IEEE TMAG
Volume :
15
Issue :
1
fYear :
1979
fDate :
1/1/1979 12:00:00 AM
Firstpage :
128
Lastpage :
130
Abstract :
A superconducting solenoid with a conductive bore tube is under construction for use with the time projection chamber (TPC) detector at PEP. It will be a uniform induction of 1.5 T over a 6.3 m3volume. Its stored energy will be 11 MJ while maintaining a radiation thickness of 0.3 radiation lengths for the coil package. The coil will operate at a current density of 7 × 108Am-2and it will be cooled by force flow two phase helium in a tube. The final design details are given here.
Keywords :
Electron storage rings; Radiation detectors; Superconducting magnets; Argon; Boring; Current density; Detectors; Helium; Packaging; Solenoids; Superconducting coils; Superconducting epitaxial layers; Superconducting magnets;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1979.1060169
Filename :
1060169
Link To Document :