• DocumentCode
    969867
  • Title

    A magnet system for the time projection chamber at PEP

  • Author

    Green, M.A. ; Eberhard, P.H. ; Taylor, J.D. ; Burns, W.A. ; Garfinkel, B. ; Gibson, G.H. ; Miller, P.B. ; Ross, R.R. ; Smits, R.G. ; Van Slyke, H.W.

  • Author_Institution
    IEEE TMAG
  • Volume
    15
  • Issue
    1
  • fYear
    1979
  • fDate
    1/1/1979 12:00:00 AM
  • Firstpage
    128
  • Lastpage
    130
  • Abstract
    A superconducting solenoid with a conductive bore tube is under construction for use with the time projection chamber (TPC) detector at PEP. It will be a uniform induction of 1.5 T over a 6.3 m3volume. Its stored energy will be 11 MJ while maintaining a radiation thickness of 0.3 radiation lengths for the coil package. The coil will operate at a current density of 7 × 108Am-2and it will be cooled by force flow two phase helium in a tube. The final design details are given here.
  • Keywords
    Electron storage rings; Radiation detectors; Superconducting magnets; Argon; Boring; Current density; Detectors; Helium; Packaging; Solenoids; Superconducting coils; Superconducting epitaxial layers; Superconducting magnets;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1979.1060169
  • Filename