DocumentCode
970426
Title
Design and operating experience of the cryogenic system of the U. S. SCMS as incorporated into the bypass loop of the U-25 MHD generator facility
Author
Niemann, R.C. ; Mataya, K.F. ; McWilliams, D.A. ; Borden, R. ; Streeter, M.H. ; Wickson, R. ; Smelser, P. ; Privalov, N.P.
Author_Institution
Argonne National Laboratory, Argonne, IL
Volume
15
Issue
1
fYear
1979
fDate
1/1/1979 12:00:00 AM
Firstpage
298
Lastpage
301
Abstract
The design features and accumulated operating experience, from a cryogenics point of view, of the United States Superconducting Magnet System (U.S. SCMS) are presented. The principal cryogenic system design parameters are enumerated. Details of the cryogenic aspects of magnet system commissioning, standby mode, and operation with MHD generators are discussed. Included are system operation, problems encountered and corrective actions taken, and measured operating parameters which include liquid helium boiloff, cryostat pressure and level versus time, etc. The aspects of the transition between operation in the laboratory and in an MHD plant are elaborated.
Keywords
MHD; Superconducting magnets; Cryogenics; Dielectric liquids; Helium; Insulation; Laboratories; Magnetic separation; Magnetohydrodynamic power generation; Nitrogen; Superconducting magnets; Temperature;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1979.1060215
Filename
1060215
Link To Document