DocumentCode :
970426
Title :
Design and operating experience of the cryogenic system of the U. S. SCMS as incorporated into the bypass loop of the U-25 MHD generator facility
Author :
Niemann, R.C. ; Mataya, K.F. ; McWilliams, D.A. ; Borden, R. ; Streeter, M.H. ; Wickson, R. ; Smelser, P. ; Privalov, N.P.
Author_Institution :
Argonne National Laboratory, Argonne, IL
Volume :
15
Issue :
1
fYear :
1979
fDate :
1/1/1979 12:00:00 AM
Firstpage :
298
Lastpage :
301
Abstract :
The design features and accumulated operating experience, from a cryogenics point of view, of the United States Superconducting Magnet System (U.S. SCMS) are presented. The principal cryogenic system design parameters are enumerated. Details of the cryogenic aspects of magnet system commissioning, standby mode, and operation with MHD generators are discussed. Included are system operation, problems encountered and corrective actions taken, and measured operating parameters which include liquid helium boiloff, cryostat pressure and level versus time, etc. The aspects of the transition between operation in the laboratory and in an MHD plant are elaborated.
Keywords :
MHD; Superconducting magnets; Cryogenics; Dielectric liquids; Helium; Insulation; Laboratories; Magnetic separation; Magnetohydrodynamic power generation; Nitrogen; Superconducting magnets; Temperature;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1979.1060215