Abstract :
The DC performances of three full- and five sub-size NbTi cable-in-conduit conductors, measured in the SULTAN test facility, are compared. In general, the self-field effect was found to cause sudden take-offs at high currents. In most of the investigated conductors the transition to sudden take-offs occurs for self-field contributions between 0.5 and 0.8 T. In the region of the sudden take-offs, the quench currents of the full-size conductors were found to be far below the critical current expected for the peak magnetic field. This behavior can be attributed to a current unbalance among the strands, which seems to be more pronounced at higher currents
Keywords :
conductors (electric); critical currents; current distribution; electric conduits; niobium alloys; superconducting cables; superconducting magnets; test facilities; titanium alloys; DC performance; ITER; NbTi; NbTi cable-in-conduit conductor; SULTAN test facility; critical current; current distribution; fusion magnet; fusion magnets; magnetic field; quench current; Conductors; Critical current; Current distribution; Magnetic field measurement; Niobium compounds; Performance evaluation; Power cables; Superconducting cables; Titanium compounds; Wires; Current distribution; fusion magnets; quench behavior;