DocumentCode :
974488
Title :
A linear accelerator bunch length monitor
Author :
Jessie, Darryl ; Norum, Eric
Author_Institution :
Saskatchewan Accel. Lab., Saskatchewan Univ., Saskatoon, Sask., Canada
Volume :
43
Issue :
3
fYear :
1996
fDate :
6/1/1996 12:00:00 AM
Firstpage :
2154
Lastpage :
2162
Abstract :
A monitor has been developed that provides an indication of the bunching efficiency of the Saskatchewan Accelerator Laboratory´s linear accelerator (linac). By adjusting the prebuncher phase at the injector, a decrease in energy spread of 15% at the end of the linac was observed. With more rigorous optimization, it is believed that a reduction of 20% or greater in energy spread can be achieved
Keywords :
beam handling techniques; electron accelerators; electron beams; particle beam diagnostics; particle beam injection; Saskatchewan Accelerator Laboratory; bunching efficiency; electron beam; energy spread decrease; injector; linac; linear accelerator bunch length monitor; prebuncher phase; Acceleration; Electron accelerators; Electron beams; Energy measurement; Helium; Laboratories; Linear accelerators; Linear particle accelerator; Monitoring; Particle beams;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.502310
Filename :
502310
Link To Document :
بازگشت