• DocumentCode
    978054
  • Title

    An improved 60 Hz superconducting power transmission cable

  • Author

    Morgan, G.H. ; Schauer, F. ; Thomas, R.A.

  • Author_Institution
    Brookhaven National Laboratory, Upton, New York
  • Volume
    17
  • Issue
    1
  • fYear
    1981
  • fDate
    1/1/1981 12:00:00 AM
  • Firstpage
    157
  • Lastpage
    160
  • Abstract
    The third in a series of 10 m, Nb3Sn cables for ac power transmission has been installed in a horizontal, refrigerated cryostat. Like the two previous ones, this coaxial cable has its ends rigidly fixed so that it cannot contract axially on cooldown, and has two layers of superconducting helices and two layers of high purity aluminum helices for stabilization in each conductor. It differs from the previous one in having thicker electrical insulation (7.4 mm vs 3.6 mm), in having increased contact resistance between the superconducting layers to reduce ac loss, and in being driven by an external supply through horizontal, coaxial, vapor-cooled current leads. This is the final short cable prior to construction late this year of a 100 m cable which will be tested with high voltage and high current simultaneously. Results of current tests are presented, including ac loss at various temperatures and recovery from thermally induced quenches.
  • Keywords
    Superconducting cables; Coaxial cables; Contracts; Niobium; Power transmission; Refrigeration; Superconducting cables; Superconducting epitaxial layers; Superconducting transmission lines; Testing; Tin;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1981.1060909
  • Filename
    1060909