DocumentCode :
979338
Title :
Measuring the transfer impedance and admittance of a cylindrical shield using a single triaxial or quadraxial fixture
Author :
Zimmerman, William R. ; Wellems, L. David
Author_Institution :
Mission Res. Corp., Albuquerque, NM, USA
Volume :
35
Issue :
4
fYear :
1993
fDate :
11/1/1993 12:00:00 AM
Firstpage :
445
Lastpage :
450
Abstract :
An experimental procedure is proposed for quickly measuring both the transfer impedance and admittance of cylindrical shields using a single triaxial or quadraxial fixture. The approach is demonstrated for circular apertures, longitudinal slots, and longitudinal strips. It is anticipated that this approach can be used to completely characterize shield faults that are intentionally introduced to increase the electromagnetic coupling to interior circuits in order to demonstrate hardness margin
Keywords :
electric admittance measurement; electric impedance measurement; electromagnetic compatibility; shielding; circular apertures; cylindrical shield; electromagnetic coupling; longitudinal slots; longitudinal strips; quadraxial fixture; shield faults; transfer admittance measurement; transfer impedance; triaxial fixture; Admittance measurement; Apertures; Circuit testing; Electromagnetic measurements; Fixtures; Frequency; Impedance measurement; Q measurement; Voltage; Yttrium;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/15.247858
Filename :
247858
Link To Document :