Title :
An automated measuring system for the antiproton accumulator magnets
Author :
Brown, R. ; Dorenbos, T. ; Frauchiger, M. ; Johnson, C.D. ; Petty, L.
Author_Institution :
European Organization (CERN), Geneva, Switzerland
fDate :
9/1/1981 12:00:00 AM
Abstract :
The diversity of magnet measurement and shimming requirements, together with the short construction period of the Antiproton Accumulator, led to the choice of an automatic measuring system for the 24 quadrupoles and 12 dipoles of the AA ring. A CAMAC based microcomputer was used for control, storage and some local reduction of measurements. In order to accomplish the extensive shimming programme the need to make continuous measurements, with in-flight acquisition of coil position and voltage, was met by the use of fast electronics and processor code subroutines for the computer acquisition of measured values. Relative position errors were less than 0.1 mm and relative field or gradient errors were 3 parts in 104.
Keywords :
Accelerator magnets; Magnetic measurements; Proton storage rings; Algorithms; Automatic control; CAMAC; Coils; Computer errors; Magnetic field measurement; Magnets; Microcomputers; Position measurement; Voltage;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1981.1061466