DocumentCode :
984710
Title :
Experimental studies of the RF-DC differences of voltage standards
Author :
Huang, Dexiang ; He, Shuizhi
Author_Institution :
Shaoxing Ind. Res. Inst., Zhejiang, China
Volume :
39
Issue :
1
fYear :
1990
fDate :
2/1/1990 12:00:00 AM
Firstpage :
10
Lastpage :
14
Abstract :
The RF-DC differences (d) of primary voltage standards have been determined by experimental and theoretical processes. Comparisons of five different types of voltage standards have been made. The RF-DC differences of some standards at frequencies from 10 Hz to 300 MHz, or even up to 1 GHz, are quite small, but the d value at frequencies from 0.1 to 50 MHz are not as small as they could be. The recommended method for determining d values is to derive an empirical formula and then to correct it from measured data. The uncertainties of primary voltage standards established by this method are ±0.007% at 1 MHz, ±0.01% at 3 MHz, ±0.02% at 10 MHz, ±0.07% at 30 MHz, ±0.15% at 50 MHz, and ±0.3% at 100 MHz
Keywords :
measurement standards; voltage measurement; 0.1 to 50 MHz; 1 MHz; 10 Hz to 1 GHz; 10 MHz; 100 MHz; 3 MHz; 30 MHz; RF-DC differences; d value; primary standard; voltage standards; Bolometers; Bridge circuits; Frequency measurement; Frequency response; Helium; Platinum; Semiconductor thin films; Thermistors; Transistors; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.50406
Filename :
50406
Link To Document :
بازگشت