DocumentCode :
987530
Title :
A design strategy for suppression of hole-pattern artifacts in high-energy collimators
Author :
Formiconi, Andreas Robert ; Gunter, Donald Lee ; Vanzi, Eleonora
Author_Institution :
Dept. of Clinical Pathophysiology, Univ. of Florence, Firenze, Italy
Volume :
53
Issue :
3
fYear :
2006
fDate :
6/1/2006 12:00:00 AM
Firstpage :
1179
Lastpage :
1187
Abstract :
Multihole collimators are the most important piece of instrumentation in determining the tradeoff between spatial resolution and noise in nuclear medicine images. Recently, we found that the collimator-to-detector gap greatly influences the hole-pattern artifacts. In addition, we also showed that specific values of the gap exist which minimize the artifacts: here we call this phenomenon "penumbral masking" (PM). In this paper, we study the matter in greater detail and we take PM into account in the problematic context of designing high-energy collimators by, basically, substituting the conventional hole-array pattern constraint with a mathematical expression of the PM effect. With this approach we found that a solution to the problem of maximizing sensitivity for a given spatial resolution always exists while, without the PM concept, in the case of lead (Pb), a solution exists below 300 KeV, a suboptimal solution can be found within the 300-320 KeV range and no solution at all exists beyond 320 KeV. Thus, one is able to minimize the hole-pattern artifacts while designing high -energy collimators even if a somewhat lower sensitivity has to be accepted: for example, with lead, at 511 KeV, sensitivity is reduced by 20% compared to what it would be without the introduction of PM. When high energies are involved, even with our approach the weight constraint is a major problem, but this does not affect the capability of reducing the hole-pattern artifacts. However, even when the theoretical solution may not be feasible, this approach clarifies the design of high-energy collimators.
Keywords :
collimators; image resolution; radioisotope imaging; collimator-to-detector gap; high-energy multihole collimators; hole-pattern artifacts suppression; lead; noise; nuclear medicine image; penumbral masking; spatial resolution; Calibration; Cameras; Collimators; Instruments; Laboratories; Lead; Neoplasms; Nuclear medicine; Positrons; Spatial resolution; Hole-array artifacts; multihole collimators;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2006.874952
Filename :
1645013
Link To Document :
بازگشت