DocumentCode
991490
Title
Thermal analysis of multibarrier interior PM synchronous Machine using lumped parameter model
Author
El-Refaie, Ayman M. ; Harris, Nathan C. ; Jahns, Thomas M. ; Rahman, Khwaja M.
Author_Institution
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
Volume
19
Issue
2
fYear
2004
fDate
6/1/2004 12:00:00 AM
Firstpage
303
Lastpage
309
Abstract
This paper presents a lumped-parameter thermal model for a multi-barrier interior PM synchronous machine. The model consists of a network of 12 thermal resistances that make it possible to estimate temperatures at 9 critical points inside the machine including the stator end windings, rotor magnets, and the bearings. The details of the model are presented and two machines are analyzed, including a 6 kW 12-pole automotive starter/alternator and a 0.5 kW 4-pole electric water pump machine. The lumped-parameter model results for both machines demonstrate good agreement with results obtained using detailed thermal finite element analysis.
Keywords
finite element analysis; permanent magnet machines; rotors; stators; synchronous machines; thermal analysis; 0.5 kW; 6 kW; automotive starter/alternator; electric water pump machine; lumped parameter model; multibarrier interior PM synchronous machine; permanent magnet machines; rotor magnets; stator end windings; thermal analysis; thermal finite element analysis; Alternators; Automotive engineering; Machine windings; Magnetic analysis; Magnets; Rotors; Stator windings; Synchronous machines; Temperature; Thermal resistance; AC machines; brushless machines; equivalent circuits; losses; optimization methods; permanent magnet machines; synchronous machines; thermal factors;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/TEC.2004.827011
Filename
1300694
Link To Document