• DocumentCode
    991531
  • Title

    A new high-sensitive magneto-optic readout technique and its application to Co-Cr film

  • Author

    Gomi, Manabu ; Abe, Masanori

  • Author_Institution
    Tokyo Institute of Technology, Meguro-ku, Tokyo, Japan.
  • Volume
    18
  • Issue
    6
  • fYear
    1982
  • fDate
    11/1/1982 12:00:00 AM
  • Firstpage
    1238
  • Lastpage
    1240
  • Abstract
    A new high-sensitive magneto-optic readout technique, which allows detection of a relatively small magneto-optic rotation angle, is proposed. This technique essentially consists of a polarization modulation method ( which allows high-sensitive readout ) and a differential method ( which allows high-speed readout ). Applying this technique to a Co-Cr film ( Cr∼ 21.5 at. % ) with perpendicular anisotropy, Kerr rotation as small as 4.3´ was detected at a signal-to-noise ratio (SNR) of about 34 dB in a 1 MHz bandwidth using a 25 mW He-Ne laser (λ = 632.8 nm ). The SNR was improved 17 dB compared to that obtained by conventional DC method. This technique is promising in the high-sensitive read-out with Co-Cr film.
  • Keywords
    Magnetooptic memories; Anisotropic magnetoresistance; Magnetic films; Magnetic heads; Magnetooptic effects; Magnetooptic recording; Mirrors; Optical modulation; Optical polarization; Perpendicular magnetic recording; Signal to noise ratio;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1982.1062141
  • Filename
    1062141