Title :
A novel continuously variable single to three phase load matching circuit
Author :
Harmon, P. ; Lavers, J.D.
Author_Institution :
University of Toronto, Ontario, Canada
fDate :
11/1/1982 12:00:00 AM
Abstract :
This paper describes a continuously variable single to three phase load matching circuit. The phase balancer is realized using two thyristor controlled inductors together with a fixed capacitor bank. It is designed to balance a variable single phase load on the three phase supply network. The paper provides a simple analysis of the phase balancer and a novel method of realizing disjoint closed loop control of the two thyristor-pair firing angles is described. The implementation of the closed loop control using a M6809 microprocessor is briefly outlined and experimental results obtained with a laboratory scale prototype are included.
Keywords :
Impedance-matching; Induction heating; Capacitors; Circuits; Furnaces; Harmonic analysis; Impedance; Inductors; Microprocessors; Reactive power; Static VAr compensators; Thyristors;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1982.1062209