DocumentCode
992306
Title
Grounding, unbalancing and length effects on termination voltages of a twinax cable during bulk current injection
Author
Antonini, G. ; Scogna, A. Ciccomacini ; Orlandi, A.
Author_Institution
Dept. of Electr. Eng., L´´Aquila Univ., Italy
Volume
46
Issue
2
fYear
2004
fDate
5/1/2004 12:00:00 AM
Firstpage
302
Lastpage
308
Abstract
By means of an equivalent SPICE circuit of a two-parallel-wires shielded cable (twinax), the effects on the induced voltages at the cable´s terminations during a bulk current injection are studied for different shield´s grounding, different cable´s asymmetries or unbalancing and different lengths of the cable. The analysis is carried out both in frequency and time domain.
Keywords
SPICE; cable shielding; earthing; electric potential; time-frequency analysis; SPICE circuit; bulk current injection; cable unbalancing; grounding; induced voltages; length effects; termination voltages; twinax cable; two-parallel-wires shielded cable; Cable shielding; Circuits; Coaxial cables; Frequency; Grounding; Impedance; Power cables; SPICE; Time domain analysis; Voltage; SPICE model; two-wires shielded cable;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.2004.826882
Filename
1300770
Link To Document