• DocumentCode
    992477
  • Title

    Performance test results of cryogenic pump system for Demonstration Poloidal Coil

  • Author

    Tada, E. ; Hiyama, T. ; Kawano, K. ; Hoshino, M. ; Yamamura, H. ; Sato, M. ; Kato, T. ; Shimamoto, S.

  • Author_Institution
    JAERI, Ibaraki, Japan
  • Volume
    24
  • Issue
    2
  • fYear
    1988
  • fDate
    3/1/1988 12:00:00 AM
  • Firstpage
    1003
  • Lastpage
    1006
  • Abstract
    The system, composed of a circulation pump and a cold compressor, is designed to produce supercritical helium with a mass flow rate of 350 g/sec at 10 bar below 4 K in normal operation. The circulation pump uses a reciprocating-pump design with double-acting bellows. The cold compressor uses a centrifugal compressor design with dynamic gas bearings. In performance tests using real cryogenic pumps for the Japan Atomic Energy Research Institute Demonstration Poloidal Coil program, it was found that the measured maximum flow rate is around 680 g/sec at a pressure head of 1.1 bar with adiabatic compression efficiency of more than 60%.
  • Keywords
    cryogenics; fusion reactor theory and design; pumps; superconducting magnets; Demonstration Poloidal Coil; adiabatic compression efficiency; centrifugal compressor design; circulation pump; cold compressor; cryogenic pump system; double-acting bellows; dynamic gas bearings; performance tests; reciprocating-pump design; Bellows; Cooling; Cryogenics; Fusion reactor design; Helium; Inductors; Superconducting coils; System testing; Vacuum systems; Voltage;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.11397
  • Filename
    11397