Performance test results of cryogenic pump system for Demonstration Poloidal Coil
Author
Tada, E. ; Hiyama, T. ; Kawano, K. ; Hoshino, M. ; Yamamura, H. ; Sato, M. ; Kato, T. ; Shimamoto, S.
Author_Institution
JAERI, Ibaraki, Japan
Volume
24
Issue
2
fYear
1988
fDate
3/1/1988 12:00:00 AM
Firstpage
1003
Lastpage
1006
Abstract
The system, composed of a circulation pump and a cold compressor, is designed to produce supercritical helium with a mass flow rate of 350 g/sec at 10 bar below 4 K in normal operation. The circulation pump uses a reciprocating-pump design with double-acting bellows. The cold compressor uses a centrifugal compressor design with dynamic gas bearings. In performance tests using real cryogenic pumps for the Japan Atomic Energy Research Institute Demonstration Poloidal Coil program, it was found that the measured maximum flow rate is around 680 g/sec at a pressure head of 1.1 bar with adiabatic compression efficiency of more than 60%.
Keywords
cryogenics; fusion reactor theory and design; pumps; superconducting magnets; Demonstration Poloidal Coil; adiabatic compression efficiency; centrifugal compressor design; circulation pump; cold compressor; cryogenic pump system; double-acting bellows; dynamic gas bearings; performance tests; reciprocating-pump design; Bellows; Cooling; Cryogenics; Fusion reactor design; Helium; Inductors; Superconducting coils; System testing; Vacuum systems; Voltage;