DocumentCode :
992622
Title :
Accurate profile extraction and mapping by intelligent processing of ultrasonic range data
Author :
Barshan, B.
Author_Institution :
Bilkent Univ., Ankara
Volume :
43
Issue :
24
fYear :
2007
Firstpage :
1396
Lastpage :
1398
Abstract :
A novel technique is described that employs intelligent processing of multiple ultrasonic range measurements for accurate surface profile extraction and mapping. It aims to overcome the intrinsic angular uncertainty of ultrasonic sensors, as well as eliminating noise and crosstalk related misreadings. Experimental verification is provided where the ultrasonic range data is acquired through wall following. The technique is evaluated based on three complementary error criteria. Compared to the most recently reported arc-transversal median algorithm, the proposed technique provides about 50% smaller mean absolute error, 28-50% higher correct detection of pixels as full and empty, and 10-15 times smaller CPU time, which is less than a tenth of a second. The method is also superior in eliminating artefacts.
Keywords :
crosstalk; ultrasonic measurement; ultrasonic transducers; arc-transversal median algorithm; crosstalk; experimental verification; intelligent processing; intrinsic angular uncertainty; ultrasonic range data; ultrasonic sensor;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20071828
Filename :
4391016