DocumentCode :
992738
Title :
Measurement of spacecraft power transformer acoustic noise
Author :
Kelley, Arthur W.
Author_Institution :
Dept. of Electr. & Comput. Eng., Raleigh, NC, USA
Volume :
26
Issue :
1
fYear :
1990
fDate :
1/1/1990 12:00:00 AM
Firstpage :
281
Lastpage :
289
Abstract :
The principal advantage of an AC power system over a DC power system in spacecraft is the use of transformers for changes in voltage. To reduce transformer weight, the power system frequency is chosen in the range of 400 Hz to 20 kHz. However, power transformers operated in this frequency range may generate unwanted acoustic noise. Measurements of the acoustic noise generated by representative power transformers over this frequency range are reported. Recommendations are given for transformer design when acoustic noise is a concern
Keywords :
acoustic noise; power transformers; space vehicle power plants; 400 Hz to 20 kHz; AC power system; power system frequency; spacecraft power transformer acoustic noise; transformer design; transformer weight; Acoustic measurements; Acoustic noise; Frequency; Magnetic cores; Magnetostriction; Noise measurement; Power measurement; Power transformers; Space vehicles; Transformer cores;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.50555
Filename :
50555
Link To Document :
بازگشت