DocumentCode :
993746
Title :
Determination of Rate of De-Ionisation of Electric Arc Vapor
Author :
Cordes, Henry G.
Author_Institution :
Radio Research Engineer, Bremerton, Washington
Volume :
7
Issue :
5
fYear :
1919
Firstpage :
527
Lastpage :
539
Abstract :
After discussing the de-ionisation and consequent loss of conductivity of mercury vapor carrying a momentary arc, the author considers an arrangement of circuits for determining the rate of de-ionisation, and the effect of this rate on the voltage required for a subsequent re-ignition. The theory of the circuits shown is given, and illustrated by numerical examples. It is suggested that the arrangements shown be experimentally carried out because of possibly important practical applications.
Keywords :
Batteries; Capacitance; Cathodes; Circuit testing; Electrodes; Inductance; Maintenance engineering; Switches; Vacuum arcs; Valves;
fLanguage :
English
Journal_Title :
Radio Engineers, Proceedings of the Institute of
Publisher :
ieee
ISSN :
0731-5996
Type :
jour
DOI :
10.1109/JRPROC.1919.217467