DocumentCode
994026
Title
Test beam results of a low-pressure micro-strip gas chamber with a secondary-electron emitter
Author
Kwan, S. ; Anderson, D.F. ; Zimmerman, J. ; Sbarra, C. ; Salomon, M.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
42
Issue
4
fYear
1995
fDate
8/1/1995 12:00:00 AM
Firstpage
419
Lastpage
422
Abstract
We present recent results, from a beam test, on the angular dependence of the efficiency and the distribution of the signals on the anode strips of a low-pressure micro-strip gas chamber with a thick CsI layer as a secondary-electron emitter. New results of CVD diamond films as secondary-electron emitters are discussed
Keywords
position sensitive particle detectors; secondary electron emission; solid scintillation detectors; C; CVD diamond films; CsI; angular dependence; anode strips; low-pressure microstrip gas chamber; secondary-electron emitter; test beam results; thick CsI layer; Anodes; Cathodes; Detectors; Energy resolution; Face detection; Glass; Signal resolution; Strips; Testing; Timing;