Title :
Position sensitive ΔE detector
Author :
Bengis, D.V.H. ; Sealock, R.M.
Author_Institution :
Dept. of Phys., Virginia Univ., Charlottesville, VA, USA
fDate :
8/1/1995 12:00:00 AM
Abstract :
A method is described for simultaneously measuring the interaction position and energy loss in a thin scintillator for energetic charged particles. Wave shifting optical fibers embedded in a scintillator combined with a Hamamatsu R2486 crossed wire anode, position sensitive photomultiplier tube are used. A prototype detector gave 2.4 mm FWHM position resolution for minimum ionizing cosmic rays. Studies to extract a single pulse linear in position from the phototube pulses using neural networks are described
Keywords :
cosmic ray apparatus; energy loss of particles; high energy physics instrumentation computing; neural nets; photomultipliers; position sensitive particle detectors; solid scintillation detectors; FWHM position resolution; Hamamatsu R2486 crossed wire anode; energetic charged particles; energy loss; interaction position; minimum ionizing cosmic rays; neural networks; phototube pulses; position sensitive ΔE detector; position sensitive photomultiplier tube; prototype detector; simultaneous measurement; single pulse; thin scintillator; wave shifting optical fibers; Current measurement; Energy loss; Energy measurement; Loss measurement; Optical fibers; Optical pulses; Particle measurements; Position measurement; Position sensitive particle detectors; Wire;
Journal_Title :
Nuclear Science, IEEE Transactions on