• DocumentCode
    994250
  • Title

    Acceleration of maximum likelihood reconstruction, using frequency amplification and attenuation compensation

  • Author

    Nuyts, Johan ; Suetens, Paul ; Mortelmans, Luc

  • Author_Institution
    Dept. of Nucl. Med., Katholieke Univ., Leuven, Belgium
  • Volume
    12
  • Issue
    4
  • fYear
    1993
  • fDate
    12/1/1993 12:00:00 AM
  • Firstpage
    643
  • Lastpage
    652
  • Abstract
    Algorithms that calculate maximum likelihood (ML) and maximum a posteriori solutions using expectation-maximization have been successfully applied to SPECT and PET. These algorithms are appealing because of their solid theoretical basis and their guaranteed convergence. A major drawback is the slow convergence, which results in-long processing times. The authors present 2 new heuristic acceleration methods for maximum likelihood reconstruction of ECT images. The first method incorporates a frequency-dependent amplification in the calculations, to compensate for the low pass filtering of the backprojection operation. In the second method, an amplification factor is incorporated that suppresses the effect of attenuation on the updating factors. Both methods are compared to the 1-dimensional line search method proposed by Lewitt. All 3 methods accelerate the ML algorithm. On the authors´ test images, Lewitt´s method produced the strongest acceleration of the three individual methods. However, the combination of the frequency amplification with the line search method results in a new algorithm with still better performance. Under certain conditions, an effective frequency amplification can be already achieved by skipping some of the calculations required for ML
  • Keywords
    computerised tomography; image reconstruction; radioisotope scanning and imaging; PET; SPECT; algorithms; attenuation compensation; backprojection operation; emission computerised tomography; expectation-maximization; frequency amplification; heuristic acceleration methods; low pass filtering; maximum a posteriori solution; maximum likelihood reconstruction acceleration; maximum likelihood solution; nuclear medicine; Acceleration; Attenuation; Electrical capacitance tomography; Filtering; Frequency; Image reconstruction; Low pass filters; Positron emission tomography; Search methods; Solids;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.251114
  • Filename
    251114