DocumentCode :
996691
Title :
Losses in Transformers for Use With Mercury Arc Rectifiers
Author :
DeBlieux, E.V.
Author_Institution :
General Trans. Engg. Dept., General Electric Co., Pittsfield, Mass.
Volume :
50
Issue :
3
fYear :
1931
Firstpage :
999
Lastpage :
1005
Abstract :
This paper developes the mathematical formulas and discusses the assumption involved in the methods for determining the losses of transformers for use with mercury arc rectifiers. The methods discussed have been proposed for the A. I. E. E. Standards. From test readings of current taken under service conditions, a rigid calculation of copper losses is made. From this calcutlation it is shown that the proposed methods give values that are accurate within satisfactory limits. The paper also presents the advantages of the proposed methods for determining the losses of transformers for use with mercury arc rectifiers.
Keywords :
Arc discharges; Circuit testing; Coils; Current supplies; Frequency; Rectifiers; Transformers;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1931.5055907
Filename :
5055907
Link To Document :