• DocumentCode
    997051
  • Title

    Smart smooth muscle spring-dampers

  • Author

    Armentano, Ricardo L. ; Barra, Juan G. ; Pessana, F.M. ; Craiem, D.O. ; Graf, Sebastian ; Santana, D.B. ; Sanchez, R.A.

  • Author_Institution
    Fac. de Ingenieria, Favaloro Univ.
  • Volume
    26
  • Issue
    1
  • fYear
    2007
  • Firstpage
    62
  • Lastpage
    70
  • Abstract
    Pulsatile pressure in arteries produces mechanical oscillations. High-frequency vibrations tend to produce mechanical structure injures. Vascular smooth muscle (VSM) could react modulating viscoelasticity to protect the arterial wall, filtering the highest harmonics component present in the large and rapid slope of blood pressure. The aim of this study was to evaluate the filtering performance exerted by vascular smooth muscle in the human common carotid artery (CCA) in normotensive (NT, smart spring-dampers turned on), hypertensive (HT, smart spring-dampers in action) and angiotensin converting enzyme (ACE) inhibitors-treated hypertensive patients (HT-treated, smart spring-dampers tuned), and in harvested human CCA segments (smart spring-dampers turned off). Human carotid arteries in vitro experiments (n=14) and in vivo studies (n=24) were performed, using adaptive modeling techniques to calculate mechanical impedance and creep (tau C) and stress relaxation (tauSR) time constants. This adaptive procedure was tested in vitro in harvested CCA mounted in a circulation mock. A confirmatory measure of damping was achieved by using the half-power bandwidth method (fC) derived from the pressure-diameter frequency dependence using Bode diagrams, i.e., a compliance transfer function (diameter/pressure). Energy dissipation was calculated from the imaginary part of this function. Low-pass frequency responses were verified with a flat plateau up to a relatively stable frequency corner fC in the Bode diagram of the complete third-order model. Simplified first-order model cutoff frequencies were 2.7, 2.8, and 3.0 Hz for NT, HT, and HT-treated, respectively, showing an interesting constancy between groups. Smooth muscle tonus proved to preserve fC as well as tauC. Energy dissipation in hypertensive patients (n=12) three-folded NT values and tended to be restored in HT-treated by means of a decrease in tauSR\n\n\t\t
  • Keywords
    Bode diagrams; biomechanics; blood vessels; cardiovascular system; creep; damping; enzymes; filtering theory; frequency response; haemodynamics; muscle; pulsatile flow; stress relaxation; transfer functions; viscoelasticity; 2.7 Hz; 2.8 Hz; 3.0 Hz; Bode diagrams; adaptive modeling techniques; angiotensin converting enzyme inhibitors-treated patients; arterial wall protection; blood pressure; creep; energy dissipation; filtering performance; half-power bandwidth method; harvested human carotid artery segments; high-frequency vibrations; highest harmonics component filtering; human common carotid artery; hypertensive patients; in vitro experiments; in vivo experiments; low-pass frequency responses; mechanical impedance; mechanical oscillations; mechanical structure injures; normotensive patients; pulsatile pressure; smart smooth muscle spring-dampers; stress relaxation time constants; transfer function; vascular smooth muscle; viscoelasticity; Carotid arteries; Energy dissipation; Filtering; Frequency; Humans; Hypertension; In vitro; Muscles; Strontium; Vibrations; Adult; Blood Flow Velocity; Blood Pressure; Cadaver; Carotid Artery, Common; Computer Simulation; Elasticity; Female; Humans; Hypertension; Male; Middle Aged; Models, Cardiovascular; Muscle, Smooth, Vascular; Viscosity;
  • fLanguage
    English
  • Journal_Title
    Engineering in Medicine and Biology Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0739-5175
  • Type

    jour

  • DOI
    10.1109/MEMB.2007.289123
  • Filename
    4069357