• DocumentCode
    998068
  • Title

    An energy recovery circuit for AC plasma display panel with series CLC resonance-SER1

  • Author

    Yang, Jin Ho ; Kim, Joong Kyun ; Whang, Ki Woong

  • Author_Institution
    Div. of PDP, Samsung SDI Co. Ltd., Chungnam, South Korea
  • Volume
    51
  • Issue
    2
  • fYear
    2005
  • fDate
    5/1/2005 12:00:00 AM
  • Firstpage
    718
  • Lastpage
    724
  • Abstract
    The switching power loss due to the panel capacitance during sustain period in AC PDP driving system can be minimized by using the energy recovery circuits. We have proposed a series CLC resonance type ERC (energy recovery circuit), SER1 (Seoul National University Energy Recovery circuit 1st). A load capacitance model was arranged for AC PDP, and the different capacitive load characteristics for the different sustain waveforms were explained. We also arranged the design procedure for SER1, and the experimental circuit was made by this guide. The experimental results of its application to a 42-inch surface discharge type AC PDP full module showed good performance of SER1 in energy recovery rate, which was measured up to 92%.
  • Keywords
    capacitance; circuit resonance; plasma displays; AC plasma display panel; SER1; Seoul National University Energy Recovery circuit 1st; driving system; energy recovery circuit; load capacitance model; panel capacitance; series CLC resonance; Capacitance; Load modeling; Plasma displays; Power system modeling; RLC circuits; Reactive power; Resonance; Surface discharges; Switching circuits; Voltage;
  • fLanguage
    English
  • Journal_Title
    Consumer Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0098-3063
  • Type

    jour

  • DOI
    10.1109/TCE.2005.1468024
  • Filename
    1468024