شماره ركورد :
163307
عنوان مقاله :
در بيماران آرتريت روماتوييد AKA طراحي و ارزيابي كيت آنتي بادي ضد كراتين
عنوان به زبان ديگر :
Designing of Anti keratin Antibody kit by Immuno fluorescent assay. (IFA) and itʹs evaluation in Rheumatoid Arthritis (RA) pathients.
پديد آورندگان :
عابديان ، فرشيده نويسنده ,
اطلاعات موجودي :
دو ماهنامه سال 1384 شماره 48
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
8
از صفحه :
18
تا صفحه :
25
كليدواژه :
Immuno fluorescent assay , پزشكي , كيت آنتي بادي ضدكراتين , Anti keratin Antibody , rheumatoid arthritis , آرتريت روماتوييد
چكيده لاتين :
Background and purpose: Rheumatoid Arthritis (RA) is a systemic auto immune Rheumatoid diseases. Auto antibodies are detected in this disease, with diagnostic and prognostic properties. One of them is AKA which reacts with the fibrous keratin in epiderm and the stratum corneum of rat esophageal epithelium. Hence at first AKA - IFA kit was designed, then its sensitivety and specificity was measured, and the titer of Anti body was evaluated in RA patients, and finaly the results of AKA were compared with that of RF test. Materials and method: AKA-IFA kit was designed with protein antigens in the stratum corneum of rat esophageal and anti human IgG conjugated to FITC. 52 patients with RA (mean age 48.0 -115.8) according to the American College of Rheumatology (ACR) criteria were selected for measuring the sensitivity and specificity. The results of AKA test in sera of RA patients were campared with 23 sera of patient control groupe (mean age 32.5 ±16.4) and 30 sera of healthy control groupe (mean age 32.1 ±16.9). Inter and intra assay method was used to determinig precision of AKA kit. RF test was also performed and itʹs results compared with result of designed AKA kit. Results: AKA were found in 75% of patients with RA ( 39 } (39152), 13% of patient 52 ) control groupe (3 (3123) and 3.3% of healthy control grouper 1 1 .(YBO)23 30 ) The designed AKA kit by inter and intra assay method had 100% and 98% percision respectively. The sensitiviety and specificity of AKA in 1 (1110) serum dilution was 75% and 92.5% to respectively but sensitiviety and specificity of RF was 88.5% , 86.8% respectively. Conclusion: According to the results, IFA- AKA test could be diagnostic and confirmative for RA , And AKA in (l/l0)serum dilution has the best diagnostic Value for RA. (cut off).
سال انتشار :
1384
عنوان نشريه :
مجله دانشگاه علوم پزشكي مازندران
عنوان نشريه :
مجله دانشگاه علوم پزشكي مازندران
اطلاعات موجودي :
دوماهنامه با شماره پیاپی 48 سال 1384
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت