بررسي قدرت آزمون شكنندگي اسمزي در تشخيص ميكروسيتيك هيپوكروميا
عنوان به زبان ديگر :
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia
اطلاعات موجودي :
دو ماهنامه سال 1384 شماره 48
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
4
از صفحه :
47
تا صفحه :
50
كليدواژه :
One tube , Osmotic fragility test , پزشكي , ميكروسيتيك هيپوكروميا , آزمون شكنندگي اسمزي , Thalassemia screening
چكيده لاتين :
Baekgrouund & purpose: Diagnosis of microcytic hgpochromia is rutinely done using automaticd equipment cell counter which is expensive and requaires expert. Personal OFT can be used for this globular defect. The aim of this study is to determine the best NaCL con centration in OFT, the experiments were done at fajer lab in 2001. Material & methods: 696 Random patients were examined simultancouly for RBV indices by cell counter &method of onetube OFT. In this test .one drop (0.05 ml) of whole blood with 5 ml of NaCl % 0.4 were mixed for 10 minutes ,and after centrifuging. Supernatal for hemolysis. Result: 382 patients with mcv> 80 had hemolysis . 228 patients with 74< mev <79 had hemolysis. 75 individuals with mcv<75 have no hemolysis and 5 with mcv>80 and 6 with 74