عنوان مقاله :
مطالعه آزمايشگاهي رفتار لرزه اي تيرهاي بتن مسلح در ساختمان هاي نيمه مهندسي تحت اثر بارهاي رفت و برگشتي و يكطرفه
عنوان به زبان ديگر :
Experimental Study of Seismic Behavior of Reinforced Concrete Beams in Semi-Engineered Buildings Under Cyclic and Monotonic Loading
پديد آورندگان :
معرفت ، محمدصادق نويسنده دانشكده مهندسي عمران- دانشگاه تهران Marefat, M.S
اطلاعات موجودي :
دو ماهنامه سال 1384 شماره 91
رتبه نشريه :
فاقد درجه علمي
كليدواژه :
شكل پذيري , ساختمان ها , زمين لرزه , ظرفيت جذب انرژي , منحني پوش , تقاضاي زلزله , Cyclic and Monotonic Loading , مهندسي , Reinforced Concrete Beams , بارگذاري رفت و برگشتي , بارگذار يكطرفه , Semi-Engineered Buildings , طرح لرزه اي , ساختمان هاي نيمه مهندسي , تيرهاي بتن مسلح
چكيده لاتين :
To assess seismic vulnerability of existing reinforced concrete buildings in Iran, cyclic and monotonic load test on six beams was carried out. Three of the specimens represented semi-engineered buildings and three of them represented well designed buildings that have been designed according to the seismic provisions of ACI318-99. Seismic provisions and standard detailing requirements are not met adequately in the semi-engineered buildings. The semi-engineered and standard specimens had similar span length and identical seismic demand in the buildings, but they differ in dimensions of the section, amount and arrangement of both longitudinal and lateral reinforcement, and concrete strength. All the specimens were half-scale and had 1250 mm length and 150 to 200 mm width. The aim was to determine seismic characteristics in terms of energy absorption capacity, ductility, and vulnerability of the beams under strong cyclic and monotonic motion. Based on the test results, parametric idealized curves for cyclic response and backbone curve of both standard and semi-engineered beams were established. The idealized curves could be used for numerical simulation of the existing buildings under seismic load. During the tests, the semi-engineered specimens showed much less strength, ductility, and energy dissipation capacity in comparison to the standard ones. The reduction in strength, ductility, and energy capacity was in average about 50, 40, and 70%, respectively. The standard specimens, that were detailed according to the intermediate ductility provisions and that is commonly applied in Iran, demonstrated relatively good cyclic capacity, but the provision of using at least 1/3rd of the main longitudinal reinforcement in the opposite side of the section seems insufficient and it is recommended to be increased to 1/2nd.
عنوان نشريه :
نشريه دانشكده فني دانشگاه تهران
عنوان نشريه :
نشريه دانشكده فني دانشگاه تهران
اطلاعات موجودي :
دوماهنامه با شماره پیاپی 91 سال 1384
كلمات كليدي :
#تست#آزمون###امتحان