شماره ركورد :
316666
عنوان مقاله :
بررسي تاثير تكنيكهاي قالبگيري بر دقت ابعادي كست نهايي ايمپلنت
عنوان به زبان ديگر :
The influence of impression techniques on dimensional accuracy of implantʹs master cast
پديد آورندگان :
مهشيد، مينو 1339 نويسنده پزشكي ,
اطلاعات موجودي :
فصلنامه سال 1384
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
13
از صفحه :
670
تا صفحه :
682
كليدواژه :
تكنيك قالبگيري , دقت ابعادي , كست نهايي ايمپلنت , Impression techniques , Implantʹs master cast , Dimensional accuracy , دندانپزشكي
چكيده لاتين :
Background & Aim: Due to the great influence of impression techniques on dimensional accuracy of implant master casts and existence of controversy about the best impression technic, this study aimed to evaluate the influence of four impression techniques on dimensional accuracy of implantʹs master cast. Methods & Materials: In this experimental study, five implantʹs analogues on laboratory models was used to transfer the positions of implants with four impression techniques. For each impression technique, 4 master casts was made. Impression techniques used included: 1 - non splinted + perforated tray, 2- non splinted + open tray, 3- splinted + open tray, 4- splinted + perforated tray. Dimensional accuracy of master casts fabricated with different impression techniques, was evaluated with comparison of distance of indicated points on the implantʹs analogues between laboratory model and master casts. The distance between points was calculated on 3 axis (X, Y, Z) and special position of points was also calculated. This evaluation was calculated with micrometer in precision of 1 micron. Data were evaluated with SPSS software and Repeated Measure analysis. Results: Significant difference was not found between the influences of four impression techniques on dimensional accuracy of implantʹs master casts. None of the four impression techniques didnʹt transfer precisely the location of indicated points of laboratory model to master casts on X, Y, Z axes or spatial position of them. Conclusion: Acrylic resin splinting didnʹt show significant influence to augment the dimensional accuracy of master casts, so the non splinted technique is advisable because of simplicity and economic. Although more investigations is needed in this issues to augment the dimensional accuracy of master casts and approach to oral situation for increasing the clinical relevance.
سال انتشار :
1384
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
اطلاعات موجودي :
فصلنامه با شماره پیاپی سال 1384
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت