عنوان مقاله :
شبيه سازي عددي درمان تومورهاي سرطاني مغز به وسيله امواج فراصوت پرشدت و متمركز بدون برداشتن استخوان هاي جمجمه
عنوان به زبان ديگر :
Numerical Investigation of the Time Reversal Mirror Technique for
Trans-skull Brain Cancer Ultrasound Surgery
پديد آورندگان :
زاهدمنش، هومن نويسنده دانشگاه صنعتي سهند،تبريز Zahedmanesh, H. , قاليچي، فرزان نويسنده دانشگاه صنعتي سهند،تبريز Ghalichi, F , بهنيا، سهراب نويسنده دانشگاه آزاد اسلامي واحد اروميه Behnia, S.
اطلاعات موجودي :
فصلنامه سال 1386 شماره 14
كليدواژه :
Brain tumor , Ultrasound thermotherapy , تومور مغزي , گرمادرماني فراصوت , روش عناصر محدود , فراصوت پرشدت و متمركز , High Intensity Focused Ultrasound , Finite element method
چكيده لاتين :
Introduction: The medical applications of ultrasound on human brain are highly limited by the phase
and amplitude aberrations induced by the heterogeneities of the skull. However, it has been shown that
time reversing coupled with amplitude compensation can overcome these aberrations. In this work, a
model for 2D simulation of the time reversal mirror technique is proposed to study the possibility of
targeting any point within the brain without the need for craniotomy and to calculate the acoustic
pressure field and the resulting temperature distribution within the skull and brain during a High Intensity
Focused Ultrasound (HIFU) transcranial therapy.
Materials and Methods: To overcome the sensitivity of the wave pattern to the heterogeneous geometry
of the skull, a real MRI derived 2D model is constructed. The model should include the real geometry of
brain and skull. The model should also include the couplant medium which has the responsibility of
coupling the transducer to the skull for the penetration of ultrasound. The clinical substance used as the
couplant is water. The acoustic and thermal parameters arc derived from the references. Next, the wave
propagation through the skull is computed based on the Helmholtz equation, with a 2D finite element
analysis. The acoustic simulation is combined with a 2D thermal diffusion analysis based on Pennes
Bioheat equation and the temperature elevation inside the skull and brain is computed. The numerical
simulations were performed using the FFMLAB 3.2 software on a PC having 8 GB RAM and a 2.4 MHz
dual CPU.
Results: It is seen that the ultrasonic waves are exactly focalized at the location where the hydrophone
has been previously implanted. There is no penetration into the sinuses and the waves are reflected from
their surface because of the high discrepancy between the speed of sound in bone and air. Under the
focal pressure of 2.5 MPa and after 4 seconds of sonication the temperature at the focus reached 51 °C
and the temperature of the pre-target bone increased to 56.3\ °C. In the post-target region the
temperature of the sphenoid bone increased to 47.1 °C while the temperature of the occipital bones
reached up to 46°C. It is also shown that by using a cold water cooling system and cooling down the pretarget
bones to 20 °C before sonication, the maximum pre-target bone temperature will not exceed 40°C
and hence the pre-target bone cells will remain intact.
Discnssion and Conelusion: In this study, it is well demonstrated that by using the time reversal mirror
technique it is possible to target any point within the skull without the need for craniotomy. Although at
higher acoustic frequencies compared to the lower ones such as 300 kHz the ultrasound undergoes more
severe aberrations while passing through media having geometrical heterogeneity and discrepant sound
velocities, the simulations performed in this work show that even at such frequencies it is still possible to
correct these aberrations using the time reversal mirror technique. The thermal simulations show that by
using this method the temperature of the deep seated tumors can be increased to cytotoxic temperature in
a few seconds.
اطلاعات موجودي :
فصلنامه با شماره پیاپی 15 سال 1386
كلمات كليدي :
#تست#آزمون###امتحان