عنوان مقاله :
طالعه جريان گاز UF6 با استفاده از اريفيس و شيرسوزني تحت شرايط خلاء متوسط و بررسي پارامترهاي مؤثر بر آن
عنوان به زبان ديگر :
Study on UF6 Gas Flow by Using Orifice and Needle Valve Under Medium
Vacuum Condition and Investigation of Effective Parameters on It
پديد آورندگان :
وطني، ضحي نويسنده دانشكده مهندسي شيمي- دانشگاه تهران Vatani, Z , صفدري، جابر نويسنده پژوهشكده علوم هسته اي- پژوهشگاه علوم و فنون هسته اي - سازمان انرژي اتمي ايران Safdari, S.J. , ابوالقاسمي، حسين نويسنده دانشكده هاي فني- دانشكده مهندسي شيمي- دانشگاه تهران Abolghasemi, H , عروج، رضا نويسنده دانشكده مهندسي شيمي- دانشگاه تهران Oruj, R
اطلاعات موجودي :
فصلنامه سال 1387 شماره 46
كليدواژه :
آهنگ جريان , افت فشار , جريان سنج ها , جريان گاز , اريفيس , شرايط خلاء متوسط , شير سوزني
چكيده لاتين :
In nuclear facility, the enrichment operation usually is carreid out under the medium and
high vacuum conditions. Measurement ofUF6 gas flow rate in the form of feed or product and tail is one
of the principal parameters in operation and production. In this facility, several orifices were used to
measure UF6 gas flow rate in the runge of lO-KO gr/hr, Due to low pressure and mass flow range,
measurement of flow rate should be made accurately. In this research, the method of flow rate
measurement in tubes by using orifice and needle valve, and also effective parameters on it, has been
studied. For the study of the gas flow rates, several orifices with different diameters were used. We
observed that for a defined orifice diameter, an increase in the input pressure causes an increase in the
flow rate and at a constant flow rate an increase in the input pressure causes a decrease in the orifice
diameter. As the pressure difference between the upside and downside of the orifice increases. the flow
rate will rise up to a certain limit. Since in all experiments of the needle valve, the ratio of outlet to the
inlet pressure is less than 0.5926. the linearity of the mass flow change versus the inlet pressure at a
constant cross sectional area shown to be consistanr with the choek current equation. Also, the
investigation of mass flow rates, when the valve is open, indicates that variations of the mass flow rate
will increase against the inlet pressure and the pressure difference. intensively.