عنوان مقاله :
مقايسه دقت فيلم هاي PRIMAX و INSIGHT و تصاوير ديجيتالي CMOS-APS در تشخيص پوسيدگي هاي جانبي دندانهاي خلفي به صورت آزمايشگاهي
عنوان به زبان ديگر :
In Vitro Comparison of the Accuracy of Primax, Insight
Dental X-Ray Films and CMOS-APS Digital Imaging in
Detection of Interproximal Caries,
پديد آورندگان :
مرامي، آناهيتا نويسنده marami, anahita , نورمحمدي، ربابه نويسنده Noormohammadi, R. , جواهري، مستانه نويسنده گروه ترميمي- دانشكده دندانپزشكي- گروه راديولوژي- دانشگاه علوم پزشكي و خدمات بهداشتي درماني قزوين Javaheri, M
اطلاعات موجودي :
فصلنامه سال 1387
كليدواژه :
راديوگرافي ديجيتال , Dental Radiography , پوسيدگي دانداني , PRIMAX , INSIGHT , راديوگرافي دنداني , Digital Radiography and Dental Caries
چكيده لاتين :
Introduction: Radiographyʹ is one of the most important diagnostic methods for evaluation of dental canes.
On the other hand. the least amount of radiation along with high qualitv is a main gold standard. The purpose
of this study was to compare the diagnostic accuracy of Primax. Insight Radiographic films, and direct
digital images (Schick CMOS-APS I. in detection of interproximal natural Caries.
Methods: In this experimental invitro study, 208 extracted permanent molars and premolars were selected for
study on the basis of varying caries depth. Exposure factors considered for conventional films and digital
images were 70 Kvp and 8 mA, and exposure times for each of the three modalities were in the following
order; 0.20 s for Primax, 0.16 s for Insight and 0.08 s for digital images. All tilm types were subsequently
automatically processed. The conventional radiographs and digital images were examined by five observers.
They "ere asked to detect caries in the approximal surfaces. They had to indicate their certainty of decision
separately for each interproximal side of each tooth on a 5-point confidence scale. Following acquisition of
(he image modalities, the teeth were sectioned rncsiodistally along the long axis of the crowns. Sectioned
teeth were evaluated for the absence or presence of approximal carious lesions as Gold Standard. Interobserver
agreement in detecting approxirnal caries, for each image using Kappa Value. was evaluated. Then
sensitivity value, specificity value and the areas (Az) beneath Receiver operating characteristic (ROC) curves
"ere calculated.
Results: A slight (k~O.OI) inter-observer agreement was observed in comparison of Gold Standard. The
sensitivity value of Prirnax was higher as compared to both Insight and digital images. Although the Az
value indicated an overall better performance of Primax(0.64) as compared to both Insight(0.63) and digital
images(O.6!), all three modalities showed a trend of increasing sensitivity for deeper lesions. Results
indicated no significant difference between the diagnostic accuracies of three imaging modalities in the
detection of approximal carious lesions (p~ 0.18). However. analysis of the diagnostic accuracy of three
imaging modalities in the detection of degree of carious lesion was significant. (p~0.02).which indicated the
superior performance of dental Elms as compared to digital images.
Conclusion: All three performed modalities are poor! in the detection of enamel lesions. Considering
limitations of this study, it is proposed that insight film and digital images should be endorsed for clinical
use, especially since radiation exposure is reduced.
عنوان نشريه :
مجله دانشگاه علوم پزشكي و خدمات بهداشتي درماني شهيد صدوقي يزد
عنوان نشريه :
مجله دانشگاه علوم پزشكي و خدمات بهداشتي درماني شهيد صدوقي يزد
اطلاعات موجودي :
فصلنامه با شماره پیاپی سال 1387
كلمات كليدي :
#تست#آزمون###امتحان