شماره ركورد :
418043
عنوان مقاله :
كارآيي فرآيند فنتون در حذف دترجنت و بهبود تصفيه پذيري بيولوژيكي پساب صنايع شوينده و پاك كننده
عنوان به زبان ديگر :
Efficiency of the Fenton Process in detergent removal and improving biological treatability of wastewater of detergent - producing industries
پديد آورندگان :
محوي، اميرحسين نويسنده دانشكده بهداشت - دانشگاه علوم پزشكي تهران Mahvi, A.H. , ناصري، سيمين نويسنده دانشكده بهداشت-دانشگاه علوم پزشكي تهران Nasseri , S , موسوي، علي رضا نويسنده دانشكده بهداشت- دانشگاه پزشكي تهران Mousavi , A.R , مصداقي نيا، علي رضا نويسنده دانشكده بهداشت و مركز تحقيقات محيط زيست- دانشگاه علوم پزشكي تهران Mesdaghinia , A.R.
اطلاعات موجودي :
فصلنامه سال 1387
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
11
از صفحه :
63
تا صفحه :
73
كليدواژه :
اكسيداسيون پيشرفته , صنعت , تصفيه بيولوژيكي , دترجنت
چكيده لاتين :
Background and Aim: Discharge of Wastewater of Cleaning Industries to environment with special physicochemical characteristics has negative cffects and in the other hand is not easily biodegradable because in these wastewaters ratio BOD5/COD is low and therefore biological treatment of them is difficult. Nowadays best method for degradation of Wastewater is advance oxidation processes .In this study investigated efficiency of Fenton process in remove anionic detergent and COD and improved from ratio of BOD5/COD. Materials and Methods: This investigating is descriptive- empirical study that paksan factory was local sampling of wastewater, 30 wastewater composite sample24|lr were taken during study period and then chemical characterization was performed by determining the following parameters: (COD? BOD, MBAS, PH, T) Then Sample of row wastewater were prepared and used in the experiments for determining the efficiency of Fenton process in treatment. Treatment experiments performed by use of various concentrations of H202 and ferrous iron at constant pH of 3and temperature of 25 in a jar test apparatus adjusted at 200 rpm and for contact time 60 min. Fe 2 on removal (COD, MBAS & BOD ) applied ANOVA. and after that for analysis of cffect H202 Results: The results of analyze showed that the concentrations of COD, ranging from 6254- 13040 mg/1 and concentration of BOD was 2590-3200mg/l and concentrations of MBAS were 245-1120 mg/l and results showed that the BOD5/COD ratio was 0.34±0.09. At constant pH of 3 and temperature of 25 for contact time 60 min, about 40% of MBAS with first concentration 470 mg/l removed by H2o2 with concentration 1800and fe^ with concentration 340 mg/l .concentration of COD reduced from 8750 to 5998 mg/l, and the ratio of BODy COD improved from 0.334 to 0.340. Conclusion: Wastewater from this industry has quality characteristics with deferent ranging and high organic load and because of high concentration of foaming thai prohibit of oxygen infiltration in wastewater and nonbiodgredable material. These wastewaters are not easily subjected to conversation svsicm of biological treatment; therefore suitable method for treatment of this wastewater should reduce organic load foaming and improve ratio of BOD^/COD advance oxidation process is one method with good efficiency for treatment of this wastewater.
سال انتشار :
1387
عنوان نشريه :
مجله دانشكده بهداشت و انستيتو تحقيقات بهداشتي
عنوان نشريه :
مجله دانشكده بهداشت و انستيتو تحقيقات بهداشتي
اطلاعات موجودي :
فصلنامه با شماره پیاپی سال 1387
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت