شماره ركورد :
418708
عنوان مقاله :
مقايسه ميزان اثر سه نوع پست پيش ساخته فلزي، فايبر كامپوزيت و سراميكي بر ميزان مقاومت به شكست دندان هاي ثناياي بالا
عنوان به زبان ديگر :
Effect of three post types on fracture resistance of maxillary central incisors
پديد آورندگان :
امين صالحي، ابراهيم نويسنده گروه ترميمي- دانشكده دندانپزشكي- دانشگاه آزاد اسلامي Amin Salehi , E , نظيري سعيد، شاپور نويسنده گروه ترميمي- دانشكده دندانپزشكي- دانشگاه آزاد اسلامي Nazere Saed , SH , فلسفي، علي اكبر نويسنده falsafi, a.a
اطلاعات موجودي :
فصلنامه سال 1387 شماره 76
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
5
از صفحه :
110
تا صفحه :
114
كليدواژه :
پست هاي كامپوزيتي , پست , پست هاي فايبر كامپوزيت
چكيده لاتين :
Background and Aim: Endodontically treated teeth, bccause of extensive structural defect, have the increased risk of fracture. For desirable reconstruction of coronal tooth structure, the post provide retention, nowadays non - metal post systems were introduced to dentistry. This study compared the fracture strength of maxillary ccntral incisors restored with metallic, fiber composite and ceramic posts. Materials & Methods: Thirty human maxillary incisors were used in this invitro experimental study. The crown of each incisor was cut off 1 mm coronal to CEJ and perpendicular to the long axis of the tooth by metal disk. The root canals of the teeth were prepared for post after root canal therapy, then three groups of 10 specimen were formed. Teeth restored with Glass fiber, ceramic and prefabricated metallic posts and numbered as group 1, 2 and 3 respectively. Then, all teeth restored with composite core (Z100, 3M) and metal crowns were fabricated and cemented with glass ionomer vitremer luting cement. Specimens were embedded in autopolimerize acrylic resin 4 mm below CEJ, and then sccurcd in a universal testing machine. A compressive load was applied at 135 degrees angle to long axis with crosshead speed of 0.5 mm/min, till fracture occurred and fracture pattern was recorded. The data were collected and analyzed using ANOVA and LSD tests. Results: Fracture resistance by Newton was respectively: 765±l 13.26, 790±95.34, and 614± 105.32 for glass fiber posts, ceramic and metallic groups. Resistance to fracture for glass fiber and ceramic posts was significantly more than Titanium post (P<0.05), but there was no significant difference between glass fiber and ceramic posts. Conclusion: Considering the results, usage of prefabricated glass fiber and ceramic posts are more preferable than prefabricated titanium posts. Because of more undesirable fracturc in ccramic posts group than glass fiber, glass fiber posts are recommended
سال انتشار :
1387
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
اطلاعات موجودي :
فصلنامه با شماره پیاپی 76 سال 1387
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت