شماره ركورد :
428695
عنوان مقاله :
بررسي چند روش معمول در تعيين نقطه محور لولايي
عنوان به زبان ديگر :
Evaluation of the accuracy of three common methods in determining hinge axis points
پديد آورندگان :
نشان دار، مرتضي نويسنده دانشگاه آزاد اسلامي تهران,دانشكده دندانپزشكي; Neshan dar, M. , آتش رزم، پارسا نويسنده دانشگاه آزاد اسلامي تهران,دانشكده دندانپزشكي; Atashrazm, P. , جلاليان، عزت الله نويسنده دانشگاه آزاد اسلامي تهران,دانشكده دندانپزشكي; Jalalian, E. , برزگرعلمداري، علي نويسنده ; Barzgar Alamdari , A. , شعبان پور، رضا نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي; Shabanpor, R.
اطلاعات موجودي :
فصلنامه سال 1388 شماره 82
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
7
از صفحه :
221
تا صفحه :
227
كليدواژه :
مفصل گيجگاهي فكي , رابطه مركزي , بيومكانيك , اكلوژن دنداني , آرتيكولاتورهاي دنداني
چكيده لاتين :
Background and Aim: Determining the true hinge axis point in order to transfer the orientation relation to articulator is of great importance in reducing occlusal errors. Because of the high cost and time consuming nature of kinematic method in determining hinge axis point, different arbitrary methods have been introduced which rendered controversial results throughout literature. The aim of this study was to evaluate some arbitrary methods for determining hinge axis point and to introduce a precise arbitrary method which has the least distance from kinematic point. Materials & Methods: This cross-sectional study was performed sequentially on 40 subjects without any TM- disorders with an age range of 21-37. At first true hinge axis point was determined by DENAR hinge axis locator and marked bilateraly on the skin. Then 3 arbitrary points (Beyron, Gysi, Tetruck & Laundeen) was also determined by a flexible ruler and marked on the skin. The distance between the arbitrary points and kinematic point was measured and the data were charted and subjected to Repeated ANOVA and Paired sample test. Results: According to the results of the study, Beyron method was significantly more accurate than the other two methods. 88.88% of Beyron points were within 3 mm distance from kinematic point, but the other points didnʹt show any significant difference with each other. Conclusion: It is concluded that Beyron method has a high accuracy as an arbitrary method and because of its proximity to the true point, application of this method is recommended.
سال انتشار :
1388
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
عنوان نشريه :
مجله دانشكده دندانپزشكي دانشگاه شهيد بهشتي
اطلاعات موجودي :
فصلنامه با شماره پیاپی 82 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت